Dexter T-80 O-Series 80lb Dryer

Dexter 80lb, O-Series, Natural Gas Dryer

Specifications

SKU: DN0080ND-15EO1C-WWKSG-USX Category: Tag:

Description

CapacityDry Weight Capacity – lb (kg)80.00(36.30)
Cylinder Volume – cu ft (L)23.00(651.30)
Speed & AirflowTumbler Speed – RPM40.00
Motor Size – Non-Reversing – 60 Hz : 50 Hz – hp (kW)0.00(0.75 : 0.56)
Motor Size – Reversing – 60 Hz : 50 Hz – hp (kW)1 & 0.75 : 1 & 0.75(0.75 & 0.56 : 0.75 & 0.56)
Airflow 8” Outlet – 60 Hz : 50 Hz – cfm (M3/min)1200 : 1000(34 : 28.3)
Dimensions & WeightCabinet Height – in (cm)75.75(192.40)
Cabinet Width – in (cm)38.50(97.80)
Cabinet Depth – Non-Reversing : Reversing – in (cm)51.75(131.40)
Door Opening – in (cm)25.63(65.10)
Floor to Door Bottom – in (cm)29.25(74.30)
Cylinder Diameter – in (cm)36.50(92.70)
Cylinder Depth – in (cm)38.00(96.50)
Lint Screen Area – sq in (sq cm)823.00(5310.00)
Net Weight – Non-Reversing : Reversing – lb (kg)715.00(324.30)
ShippingShipping Weight – Non-Reversing : Reversing – lb (kg)770.00(349.30)
Shipping Height – in (cm)80.75(205.10)
Shipping Width – in (cm)40.25(102.20)
Shipping Depth – Non-Reversing : Reversing – in (cm)55.50(141.00)
GasGas Supply Connection – in (mm)0.75(19.10)
Natural Gas Supply (Water Column) – in (cm)0.63(12.7-20.3)
LP Gas Supply (Water Column) – in (cm)11 1/2-13 1/2(29.2 – 34.3)
Gas Usage – 60Hz : 50 Hz – BTU/hr (kW)215,000 : 195,000(63 : 57.1)
ElectricalGas ModelsVolts / Hz / Phase / WiringCircuit Breaker Amps / Running Amps / Wire Size / Reversing Availability
-10120 / 60 / 1 / 2 wire ground15 / 10.4 / #12 / Reversing
-11208-240 / 60 / 1 / 2 wire ground15 / 5.5 / #12 / Reversing
-15208-240 / 60 / 1 / 2 wire ground15 / 5.5 / #12 / Non-Reversing
120 / 60 / 1 / 2 wire ground15 / 10.4 / #12 / Non-Reversing
-39230 / 50 / 1 / 2 wire ground10 / 5.2 / 2.1 mm2 / Reversing & Non-Reversing
InstallationMinimum Clearance Between Machines – in (cm)0.000.00
Minimum Clearance Behind Machines – in (cm)18.00(45.70)
Make-Up Air Required – sq ft (sq cm)1.50(1394.00)
Exhaust Size – in (cm)8.00(20.30)
Max. Exhaust Back Pressure (Water Column) – in (mm)0.30(7.60)
Recommended Exhaust Length – ft (m) & 2 elbows14.00(4.30)
OptionsControlsO-Series
ReversingOption
Other Features & OptionsMoisture Detection, Fire Response